8 isolated digital inputs
Dry contact, PNP and NPN field devices with integrated counters and configurable filtering.
Varian Titania Super I/O
Titania memperluas sambungan digital peringkat lapangan melalui I/O Modbus RTU terpencil, logik tempatan dan perlindungan industri untuk automasi teragih.
Keupayaan utama
Titania menggabungkan I/O berketumpatan tinggi, diagnostik dan fungsi edge dalam modul rel DIN yang padat.
Dry contact, PNP and NPN field devices with integrated counters and configurable filtering.
Isolated high-side sourcing outputs for 24 VDC loads, with PWM support and programmable safe values.
Hardware logic, autonomous sequencing, alarm annunciation and local PWM operating modes.
Galvanic isolation, reverse-polarity protection, current limiting, thermal shutdown, ESD, EFT and surge protection.
System, communication and per-channel input/output LED indications support commissioning and troubleshooting.
Configure address, communication and operating mode through DIP switches and Modbus registers.
Mod operasi boleh dikonfigurasi
Sahkan pendawaian, penarafan dan kesesuaian akhir dengan lembaran data terkawal terkini sebelum pemasangan.
| Mod | Fungsi | Kegunaan lazim |
|---|---|---|
| Normal Modbus Slave | Standard Modbus RTU operation using a software-configured slave ID from 1 to 247. | Central PLC, RTU, IPC or SCADA monitoring and control. |
| Hardware Logic Gates | Per-output input masks support AND, OR, XOR, NAND, NOR and XNOR relationships. | Local interlocks and deterministic field actions independent of routine host polling. |
| Pattern Matching | Detects a configured 8-bit input pattern with optional polarity inversion for each input. | Machine-state recognition and compact interlock conditions. |
| Programmable Sequencer | Linear or pendulum sequences with channel mask, step interval, pulse width, inter-sequence delay and repeat control. | Valve sequencing, backwash cycles and repetitive machine actions. |
| Alarm Annunciator | Selected inputs drive steady or blinking outputs using active-high or active-low logic and a configurable flash interval. | Local panels, stack lights, sirens and machine alarm functions. |
| PWM / PID Control | Per-channel PWM includes frequency, duty, ramping, hold, minimum and maximum intensity; supported modes add smoothing, noise tolerance and PID auto-tune. | Time-proportional loads, controlled intensity and supported closed-loop applications. |
| Frequency Simulator | Generates triangle, sawtooth, square or sine frequency patterns between configured limits. | Simulation, test and controlled frequency-output applications. |
| Safe-State Controller | Programs every output for power-up and communications-loss conditions. | Deterministic recovery and network-failure behaviour. |
Spesifikasi teknikal
Sahkan pendawaian, penarafan dan kesesuaian akhir dengan lembaran data terkawal terkini sebelum pemasangan.
8 channels; dry contact, PNP or NPN; 1 kHz maximum input frequency; 32-bit counter per channel; filter selections from Off and 1 microsecond through 100 milliseconds.
8 isolated high-side sourcing outputs; 0.7 A continuous per channel; approximately 1.1 A peak/current limit; PWM 1-50 Hz at 1% steps.
1 x isolated RS-485, 2-wire half duplex; Modbus RTU; 9600, 19200, 38400 and 115200 baud with auto-baud detection; 8N1, 8N2, 8E1 and 8O1.
24 VDC nominal, 19.2 to 28.8 VDC operating range; 2-3 W system consumption excluding external output loads.
161 x 80 x 20 mm; integrated DIN-rail mounting.
-20 C to +70 C operating; -40 C to +85 C storage; 10-95% RH non-condensing.
ESD IEC 61000-4-2, EFT IEC 61000-4-4 and surge IEC 61000-4-5 protection levels stated in the controlled datasheet.

Dokumen terkawal semasa
ID Dokumen TTN-DS-2026-001 · dikeluarkan 19 Julai 2026
Sahkan pendawaian, penarafan dan kesesuaian akhir dengan lembaran data terkawal terkini sebelum pemasangan.
Wawasan teknologi
Panduan praktikal berdasarkan bahan teknikal PyXis dan Titania semasa.
Artikel teknologi
Why remote I/O becomes more resilient when it can continue selected logic, sequencing and safe-state functions without the host controller.
Baca lagi
Artikel teknologi
How to select the input mode, reference common and filtering for switches and industrial sensors.
Baca lagi
Artikel teknologi
Design considerations for 1 kHz digital inputs, 32-bit counters, edge selection and reliable pulse capture.
Baca lagi
Artikel teknologi
How protected 24 VDC sourcing outputs should be applied to solenoids, relays, lamps and other industrial loads.
Baca lagi
Artikel teknologi
How deterministic power-up and communication-loss behaviour improves distributed I/O resilience.
Baca lagi
Artikel teknologi
Applying Boolean logic, pattern recognition, timed sequences and annunciation functions within distributed I/O.
Baca lagiBincangkan aplikasi Titania anda
Semak jenis input, beban output, logik tempatan, komunikasi, pengasingan dan keperluan kabinet dengan pasukan kami.