Artikel
DiterbitkanMotor Vibration Sensor Placement: When to Measure Both Bearing Ends
Choose drive-end and non-drive-end measurement points, validate axis and location tags, and commission a repeatable two-point motor vibration baseline.
Wawasan
Dari sensor dan Super I/O hingga komputasi edge, integrasi protokol, dan analitik kesehatan mesin, kami menghubungkan proses fisik ke dasbor operasional. Pendekatan dari lapangan hingga perusahaan ini memberi pelanggan satu jalur rekayasa yang terpadu dari pengukuran menuju tindakan.
Informasi teknis diterbitkan
Pengolahan air, transportasi, pemurnian minyak sawit, depot bahan bakar, gardu induk, manufaktur, pemantauan fasilitas, dan sistem kendaraan.
Artikel
DiterbitkanChoose drive-end and non-drive-end measurement points, validate axis and location tags, and commission a repeatable two-point motor vibration baseline.
Artikel
DiterbitkanA practical engineering method for motor run-hour counters using Titania digital inputs: distinguish starter energisation, proven operation and unknown states.
Artikel
DiterbitkanUse hysteresis, persistence and raw vibration trends to stabilise PyXis/SCADA alerts. Commission clear-state logic, data quality and machine protection under realistic operating conditions.
Artikel
DiterbitkanA PLC can read the wrong Modbus word with no communications alarm. Learn why holding register 40001 normally becomes PDU address zero, and how to prove offsets…
Artikel
DiterbitkanCommission motor-overload auxiliary-contact alarms using Titania remote I/O while keeping motor protection independent. Practical wiring, data-quality and acceptance checks.
Artikel
DiterbitkanA practical motor-maintenance checklist for inspecting PyXis vibration sensor cables, mounting, connectors, Modbus communication and post-repair baselines.
Artikel
DiterbitkanISO 20816-3:2026 has replaced the 2022 edition. A practical PyXis monitoring review covering machine scope, speed and load context, sensor data and alarm validation.
Artikel
DiterbitkanA practical Titania remote-I/O fault-finding sequence for Modbus RTU dropouts when 24 VDC outputs switch: measure supply dips, verify RS-485 evidence and protect PLC data quality.
Artikel
DiterbitkanWarm Deepavali wishes from Tachyonic Intelligence Sdn Bhd.
Artikel
DiterbitkanA practical motor start-up vibration acceptance workflow: separate acceleration transients from steady-state machine faults with PyXis monitoring and operating evidence.